Pelco FR8308 Stereo Receiver User Manual


 
16 C1647M-A (6/06)
CONNECTIONS
Connections to the FT8308 transmitter and the FR8308 receiver are made on the rear panel of the
modules and consist of the following:
Power connection
NOTES:
A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when
used as a stand-alone module. A 12 VDC power supply is provided. If a 24 VAC power
supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as
Class 2 and rated as 24 VAC, 500 mA
(minimum output).
In extreme temperature conditions, it is recommended that an industrial-rated outdoor
power supply such as the Pelco WCS1-4 power supply be used.
Fiber connection
Video input connections (transmitter only)
Video output connections (receiver only)
Figure 7 provides an illustration of FT8308 transmitter/FR8308 receiver connections.
Figure 7.
FT8308 Transmitter/FR8308 Receiver Connections
FIBER
OPTIC
CABLE
COAXIAL
CABLE
COAXIAL
CABLE
COAXIAL
CABLE
COAXIAL
CABLE
5
6
7
8
COAXIAL
CABLE
COAXIAL
CABLE
COAXIAL
CABLE
COAXIAL
CABLE
POWER/ALARM
CONNECTION FOR
RACK-MOUNTED MODULE
POWER CONNECTION
FOR STAND-ALONE MODULE