mode selection
The three-position,recessed Mode Select switch (located on the rear panel)
configures the amplifier for Stereo, Parallel or Bridged mode. Amplifiers are
factory-configured for Stereo mode. Shut the amp off before changing
modes.
stereo
In Stereo mode,both channels operate independently,with their input atten-
uators controlling their respective levels.Signal at Channel As input produces
output at Channel As output,while signal at Channel Bs input produces out-
put at Channel Bs output.Recommended minimum nominal load impedance
for stereo operation is 2 Ohms per channel.
parallel
When set to Parallel mode, program material applied to Channel As input
will appear at both Channel A and B outputs.The attenuator for Channel A
controls the level for both A and B outputs.
bridged
Bridged mode straps both amplifier channels together to make a single-
channel monaural amplifier. One channel
pushes and the other pulls equally,
increasing the power output over that of either channel alone
(see Specifications). Signal is applied to the Channel A input only. Channel
As attenuator is used to control signal level.
Use extreme caution when operating the amplifier in Bridged mode. Never
ground either side of the speaker cable when the amplifier is in Bridged
mode; both sides are hot.
If an output patch panel is used, all connections must be isolated from each
other and from the panel.The recommended minimum nominal load imped-
ance in the Bridged mode is 4 ohms, which is the equivalent to driving both
channels separately at 2 ohms.
seeconnections for examples of mode-specific wirings
Connecting amplifier
outputs to oscilloscopes
or other test equipment
while the amplifier is
in
bridged mode may
damage both the amplifier
and test equipment!
a
LT / ST owners manual
operation modes
4