Pass Labs X600.5 Stereo Amplifier User Manual


 
9
X600.5 Owners Manual
All figures obtained after 1 hour warmup, with regulated 120 VAC
power line. See manual notes about AC power line regulation.
Gain 30 dB
Freq. Response -3 dB at 1Hz, -3 dB at 100 Hz
Power Output 600 watts maximum @ 1% THD,
1 kHz, 8 ohms
Maximum Output Voltage plus, minus 110 volts
Maximum Output Current plus, minus 25 amps
Input Impedance 22 kohm balanced
Damping factor 250 ref 8 ohms nominal
Slew rate plus, minus 50 V/uS
Output Noise 400 uV unweighted 20-20 kHz
Balanced CMRR -60 dB @ 1 kHz (input common
mode rejection ratio)
DC offset < 100 mv differential
Power Consumption 550 watts idle, 1800 watts max.
Temperature 25 degrees C. above ambient at idle
Dimensions 19 “ W x 22” D x 11.5” H
Shipping Weight 150 lbs.
For more information please contact:
Pass Laboratories Inc.
P.O. Box 219,
24449 Foresthill Rd.,
Foresthill, CA 95631
Tel: 530.367.3690
Fax: 530.369.2193
www.passlabs.com
© 2006 Pass Laboratories Inc.
X600.5 Specifications
“Pass”, “pass”, “Pass Labs”, “Pass Laboratories”, Supersymmetery”,
“Aleph”, and “Zen” and are all registered trademarks of Pass
Laboratories, Inc., and all rights thereto are protected by law.