Oregon Scientific PS-L06 Stereo System User Manual


 
EN
BAROMETRIC TREND
The barometric trend arrow for the last 30 minutes is
always displayed.
VIEW THE LAST 24 HOURS
Press SELECT 2 times until the Barometer Area
flashes. Then, press UP or DOWN to view the last 24
hours history.
SET UNIT AND ALTITUDE
You can set the unit of measurement (mb/hPa or inHg)
and altitude. Setting the altitude allows the product to
take more accurate barometric measurements.
1. Press SELECT 2 times until the Barometer Area
flashes.
2. Press and hold SELECT for 2 seconds.
3. Select altitude (-100 meters to 2500 meters in
increments of 10) and the unit of measurement
(mb/hPa or inHg). Press UP or DOWN to
change the setting. Press SELECT to confirm.
14
Trend
Description Pressure change
(mb/hPa)
Rising +3
Steady Steady
Failing -3
1 hr 6 hr
+1
Steady
-1
PS-L06_GB-final.p65 8/8/03, 12:02 PM16