Omron V600-HA Stereo Amplifier User Manual


 
8 Intelligent Flag I/II V600-HA
Combinations with the V600-HS67 Sensor
Transmission Time
The transmission time refers to the time required for communications between the Sensor and the Data Carrier. It is used for calculating the travel
speed of the auto command.
Example: Combinations with the V600-HAR91, V600-HS63, and V600-D8KR04 Sensors.
Note: 1. The DC speed varies depending on transmission distance Y
and the axial offset. It is recommended that you refer to the
transmission range graphs and use the product where the
range is the largest.
2. This calculation is intended as a guideline only. Perform a
test with the actual product prior to use.
3. This equation does not include transmission error process-
ing.
Y
X
X02040608020406080
60
20
40
Y
80
0–20–40–60–80 20 40 60 80
80
60
20
40
X
Y
Y
XX
0–20–40–60–80–100 20 40 60 80 100
100
80
60
20
40
X
Y
Y
X
0–20–40–60–80
100 20 40 60 80 100
100
80
60
20
40
X
Y
Y
X
0–20–40–6080 20406080
80
60
20
40
X
Y
Y
X
0–20–40–6080 20406080
80
60
20
40
X
Y
Y
X
0–40–80–120 40 80 120
120
40
80
X
Y
Y
X
V600-HS67 & V600-D23P66N V600-HS67 & V600-D23P66SP V600-HS67 & V600-D23P71
V600-HS67 & V600-D23P72 V600-HS67 & V600-D8KR12 V600-HS67 & V600-D8KR13
V600-HS67 & V600-D8KR04
DC speed
(conveyor
speed)
=
Distance travelled in the transmission range
Transmission time
Model V600-HAR91/-HAR81/-HAM91/-HAM81 V600-HAR92
Read Write Read
Mode type DATA READ mode,
VERIFY READ mode
BYTE mode BIT SET mode, BIT
CLEAR mode
DATA READ mode
Data Carrier type EEPROM 75 ms 138 ms 150 ms 77 ms
SRAM 60 ms 95 ms 107 ms 62 ms
0–20–40–60–80 20 40 60 80
Y
X
20
40
60
80
Y
X
DC speed
(conveyor
speed)
=
75 (mm)
60 (ms)
=
75 × 10
-3
(m)
60 × 10
-3
× 1/60 (min)