Mitel 3300 Stereo Amplifier User Manual


 
7/4/2004 Page 7 of 22
ANI/DNIS/ISDN Number Delivery Yes
Link Descriptor Assignment
Number: 4
Address for Message Control:
BER - Maintenance Limit, 10**-n: 4
BER - Service Limit, 10**-n: 3
Data Call Alternate Digit Inversion: Yes
Framing Losses in 24 hrs - Maintenance Limit: 255
Framing Losses in 24 hrs - Service Limit: 9000
Integrated Digital Access: T1D4
Satellite Link Delay: No
Slip Rate - Maintenance Limit (slips/24hr.): 5000
Slip Rate - Service Limit (slips/24hr.): 7000
Alarm Debounce Timer -
Service Limit (millisec.):
500
Voice Encoding: Invert
Data Encoding: Nil
QSIG Private Network Access: No
Digital Link Fault Delay Timer (sec.): 240
Termination Mode: NT
T1 Only:
B8ZS Zero Code Suppression: Yes
Operation Mode: DSX-1
CSU Tx Line Build-Out (dB.):
DSX-1 Line Length (Ft.): 0-133
Extended Super Frame: No
Inverted D channel ( DPNSS only ): No
E1 Only:
CRC-4 Enabled: No
E1 Line Length (Ft.): 0-133
E1 Impedance (Ohms): 120
Digital Link Assignment
Controller
Module
Port Unit
Shelf
Slot
Link
Interface Type
Digital
Link
Descriptor
Comment
1 1 6 1 1 1 UNIVERSAL T1
4 Remoteability
1 1 6 1 1 2 UNIVERSAL T1
4 T1D4