Linear wt00z-1 Satellite Radio User Manual


 
3
Adjusting Dim Rate
For example: There are 3 sets of parameters that can adjust the dimming
rate of the WT00Z-1.
1. One set to control how fast the dim rate is when the dimmer receives
a Z-Wave command excluding ALL ON or ALL OFF command.
2. One set to control how fast the dim rate is when the dimmer is
locally controlled.
3. One set to control how fast the dim rate is when the dimmer receives
an ALL ON or ALL OFF command.
These values can be changed instantly to allow various scenes and
effects. The fi rst of these parameters is the “dim step” (dim rate)
parameter. It can be set to a value of 1 to 99. This value indicates how
many levels the dimmer will change when the timer (discussed below)
expires. The second parameter is the timing (how fast the dim rate)
parameter. It can be set to a value of 1 to 255. This value indicates in 10
millisecond resolution, how often the dim level will change. For example,
if you set this parameter to 1, then every 10mS the dim level will change.
If you set it to 255, then every 2.55 seconds the dim level will change.
With the combination of the two parameters that can control the dim
rate, the dimmer can be adjusted to dim from maximum to minimum or
minimum to maximum at various speeds between 10 millisecond and
252.45 seconds (over 4.25 minutes).
• Parameter 7-12
Length: 1 Byte
Valid Values: (See next)
NOTE: that this only affects a level that is reported or possibly sent by
the WT00Z-1 since the WT00Z-1 does not control a load.
On/Off Command dim rate (excluding ALL ON/ALL OFF commands)
• Parameter 7
Dim step Parameter (default = 3)
• Valid Values: 1-99
• Parameter 8
Dim timer Parameter (default =10)
• Valid Values: 1-255
Local Control dim rate
• Parameter 9
Dim step Parameter (default = 3)
• Valid Values: 1-99
• Parameter 10
Dim timer Parameter (default = 10)
• Valid Values: 1-255
ALL ON/ALL OFF dim rate
• Parameter 11
Dim step Parameter (default = 3)
• Valid Values: 1-99
• Parameter 12
Dim timer Parameter (default = 10)
• Valid Values: 1-255
Disable Group 4 During a Dim Command
After the WT00Z-1 is commanded to stop dimming when dimming
because of the DIM START command, it will then command the Z-Wave
devices that are in Group 4 to its new level. To prevent the WT00Z-1
from commanding the Z-Wave devices in Group 4 during this particular
occurrence, set Parameter 13 to the value of 1.
• Parameter 13
Length: 1 Byte
Valid Values = 0 or 1 (default 0)
NOTE: This only affects a level that is reported or possibly sent by the
WT00Z-1 since the WT00Z-1 does not control a load.
Enable Shade Control Group 1
The WT00Z-1 can control shade control devices via its group 1 if this
confi guration parameter is set to 1.
• Parameter 16
Length: 1 Byte
Valid Values = 0 or 1 (default 0)
Enable Shade Control Group 2
The WT00Z-1 can control shade control devices via its group 2 if this
confi guration parameter is set to 1.
• Parameter 14
Length: 1 Byte
Valid Values: 0 or 1 (default 0)
Enable Shade Control Group 3
The WT00Z-1 can control shade control devices via its group 3 if this
confi guration parameter is set to 1.
• Parameter 15
Length: 1 Byte
Valid Values: 0 or 1 (default 0)
LED Transmission Indication
The WT00Z-1 will fl icker its LED when it is transmitting to any of its 4
groups. This fl ickering can be set to not fl icker at all (set to 0), to fl icker
the entire time it is transmitting (set to 1), or to fl icker for only 1 second
when it begins transmitting (set to 2). By default, the WT00Z-1 is set to
fl icker for only 1 second.
• Parameter 19
Length: 1 Byte
Valid Values = 0 , 1, 2 (default 2)
Poll: Minutes
The WT00Z-1 will poll the fi rst node in Group 1 in order to keep itself
synchronized with the group if this confi guration parameter is set to 1.
How often it will poll is confi gured using this parameter.
• Parameter 20
Length: 1 Byte
Valid Values = 1 through 255 (default: 2)
Poll First Node in Group 1
The WT00Z-1 will poll the fi rst node in Group 1 in order to keep itself
synchronized with the group if this confi guration parameter is set to 1.
• Parameter 21
Length: 1 Byte
Valid Values = 0 , 1 (default 0)
Each Confi guration Parameter can be set to its default setting by setting
the default bit in the Confi guration Set command. See your controller’s
instructions on how to do this (and if it supports it). All Confi guration
commands will be reset to their default state when the WT00Z-1 is
“reset” thus removing it from the Z-Wave network.
SPECIFICATIONS
Power: 120 VAC, 60 Hz
Signal: (Frequency) 908.42 MHz
Range: Up to 100 feet line of sight between the Controller
and /or the closest EGC Receiver Module
INTEROPERABILITY WITH Z-WAVE DEVICES
A Z-Wave™ network can integrate devices of various classes, and these
devices can be made by different manufacturers. The WT00Z-1 can be
incorporated into existing Z-Wave™ networks. The top or bottom of the
WT00Z-1 switch paddle can be used to carry out inclusion (adding to
the network by adding to a group), association (operate simultaneously
with other nodes), exclusion (remove from a group) or reset (remove
from the network). Controllers can be replicated in order to provide
operation from other locations.