1
3
2
T
u
r
n
t
o
O
P
E
N
T
u
r
n
a
n
d
P
u
s
h
t
o
C
L
O
S
E
1.) Retractable feet - Located on the cabinet bottom toward the front, there are two feet that
extend downward to allow for tilt back operation. Twist while applying pressure to release these
feet. Once extended, twist further to lock in position. Reverse process for retracting.
2.) AC Power Cord Receptacle -
3.) Fuse
AC power cord can be removed for easy storage and
replacement if damaged. Insert the AC cord (provided) firmly into the AC receptacle. NOTE:
Replace the AC power cord if protective jacket is damaged or ground pin is damaged or
removed.
- The fuse is located in a fuse tray just below the receptacle. Replace only with same type
and size. For your convenience, a spare fuse is located inside the fuse tray toward the front. To
replace fuse, remove AC power cord. Remove fuse tray by pulling the tab located above the
fuse symbol away from the receptacle.
HV 65 Extras™
8