InFocus 3534324301 Home Theater System User Manual


 
Manual del usuario de IN3138HD
58
Función Comando RW Mín. Máx.
Predeter
minado
Paso Parámetro
16V Color Temp TMP RW 0 2
Source
Specific
1
Valid only when Display
Mode = User
0:Warm
1:Normal
2:Cold
17V Contrast CON RW 0 100 50 1
Valid only when Display
Mode = User
18V Current Source SRC RW 0 13 0 1
0:VGA1
1:VGA2
5:HDMI-1
7:DP
12:Video
13:S-Video
21V Digital Zoom DZM RW -10 10 0 1 -10~10
27V Error Condition ERR R n/a n/a n/a n/a
0:No error
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5: Overheating
7: Case open
8:DMD error
9:Color wheel
28V Factory Reset RST W n/a 1 1 1 1:reset
32V Freeze Screen FRZ RW 0 1 0 1 0:Disable
34V Gamma GTB RW 0 5
Source
Specific
1
Valid only when Display
Mode = User
0:1.8
1:2.0
2:2.2
3:2.4
4:B&W
5:Linear
40V Horz. Position HPS RW -5 5 0 1
RGB source only
(HPS?) to get range
45V
Lamp Hours in High
Power Mode
LMO R 0 9999
Displays the number of
hours that the current lamp
has run in High Power
(Normal) mode.
46V
Lamp Hours in Low
Power Mode
LME R 0 9999
Displays the number of
hours that the current lamp
has run in Low Power (Eco)
mode.
47V Lamp Life LIF R n/a Note
280W lamp life 3000 on
E20.8
49V
Lamp Resets (Total
number)
LMR R 0 9999 0 1
62V Lamp Low Power IPM RW 0 1 0 1 0=ECO, 1=Normal