34-ST-03-57
Page 23
STR9xx
TABLE III - OPTIONS Selection
3D 4G
None 00
••
Communication Options
HART 5.x Protocol Compatible Electronics HC
ee
H6
ee
FOUNDATION Fieldbus Communications FF
rr
Indicating Meter Options
Analog Meter (0-100 Even 0-10 Square Root) ME
••
Smart Meter SM
••
Custom Configuration of Smart Meter CI
mm
Local Zero LZ
xx
Local Zero and Span ZS
ss
Transmitter Housing & Electronics Options
NAMUR Failsafe Software NE
15 15
SIL 2 - TÜV Certified transmitter
(
requires HC and WP options
)
14 14
Lightning Protection LP
••
Custom Calibration and I.D. in Memory CC
••
Transmitter Configuration TC
••
Write Protection (Delivered in the "enabled" position) WP
••
Write Protection (Delivered in the "disabled" position) WX
••
316 SS Electronics Housing - with M20 Conduit Connections SH
nn
1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC) A1
nn
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter A2
uu
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit A3
ii
Adapter (use for FM and CSA Approvals)
Stainless Steel Customer Wired-On Tag TG
••
(4 lines, 28 characters per line, customer supplied information)
Stainless Steel Customer Wired-On Tag (blank) TB
••
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)
aa
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)
aa
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)
aa
End Cap Live Circuit Warning Label in German (only with ATEX 3D)
aa
Meter Bod
y
O
p
tions
(
Seal bolt material depends on Transmitter bolt material
)
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads CR
•
316 SS Bolts and 316 SS Nuts for Process Heads SS
•
B7M Bolts and Nuts for Process Heads B7
•
Remote Seal Options
Gold Plated Seal Diaphragm (1 Seal) G1
jj
Gold Plated Seal Diaphragm (2 Seals) G2
j
Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking N1
jj
Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking N2
j
Transmitter Mounting Brackets Options
Mounting Bracket - Carbon Steel MB
••
Mounting Bracket - 304 SS SB
••
Flat Mounting Bracket FB
••
Services/Certificates Options
Users Manual Paper Copy (Standard, HC or FF ships accordingly)
••
Clean Transmitter & Seals for Oxygen or Chlorine Service with Certificate 0X
hh
Over-Pressure Leak Test with F3392 Certificate TP
••
Calibration Test Report and Certificate of Conformance (F3399) F1
••
Certificate of Conformance (F3391) F3
••
Certificate of Origin (F0195) F5
••
FMEDA Certificate (SIL 1) F6
••
NACE Certificate (F0198) F7
o
•
NACE Certificate (F0198) for welded meter bodies only F8
16
Marine Type Approvals (DNV, ABS, BV & LR) MT
22
Warranty Options
Additional Warranty - 1 year W1
••
Additional Warranty - 2 years W2
••
Additional Warranty - 3 years W3
••
Additional Warranty - 4 years W4
••
Table III continued next page
SP
HART 6.x Protocol Compatible Electronics
PG
UM
SL
b
b
b
b
TL
GE
b
b
b
b
b
b
b