GENERAL CHARACTERISTICS
1. Rules and Regulations
CCIR Rec. 493 (Class A), 541
IMO Res. A609 (15), CEPT TR/34-01
2. Distress Call and Message
Distress Call and Message (RR3112: Format specifier
(distress), Self-ID, Nature of distress, Distress coordinates,
Time, Telecommand, EOS, ECC)
3. Class of Emission
DSC: F1B/J2B (J2B w/FS-1562)
Voice:J3E, H3E (2182 kHz)
TTY: F1B/J2B (J2B w/FS-1562)
4. Manual Setting or Scan of Distress Frequencies
MF/HF DSC:
2187.5, 4207.5, 6312, 8414.5, 12577, 16804.5 kHz
Corresponding MF/HF NBDP (not scanned):
2174.5, 4177.5, 6268, 8376.5, 12520, 16695 kHz
TP: 2182, 4125, 6215, 8291, 12290, 16420 kHz
5. Message Storage
Receive:
50 distress messages max. plus 50 non-distress messages
Transmit:
50 non-distress messages plus 99 files containing station ID,
telephone no., frequency, etc.
6. Nav Data
IEC61162
7. Alarms
Aural and visual on receipt of distress, urgency or general
calls
8. Display
24 characters x 2 lines
Character composition: 5 x 7 dots
LCD with adjustable backlighting
9. Modulator and Demodulator
Level: -30 dBm to +10 dBm at 600 ohms, balanced
Frequency: Mark 1615 Hz, Space 1785 Hz, 100 baud
Stability: ±0.5 Hz
RECEIVER CHARACTERISTICS OF DSC-6A
Receive Frequency: 2187.5 kHz
Sensitivity: Error rate 1 % at 0 dBµV
POWER SUPPLY
10.8 - 40.0 VDC, 15 W
115/230 VAC thru AC/DC changeover supply
EQUIPMENT LIST
Standard
1. DSC terminal
2. Installation materials and spare parts
Optional
1. Mounting bracket
2. Printer PP-500
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
SPECIFICATIONS OF DSC-6/6A
99043N Printed in Japan
24 VDC
VCTF-1.25
x 2C, 3 m
Operator’s room
Distress
message
controller
DMC-5
Centralized control/monitoring
Captain’s room
CO-SPEVV-SB-C
0.2 x 2 P, 30 m max.
Alarms
DSC-6/6A standard system
PRINTER
PP-500/510
115 or 230 VAC 24 VDC
Position data
Distress alarms
ALLWAVE RECEIVER
RV-107
DPYC-1.25
57FE-338-205W, 5 m
Setting telecommand,
working freq., etc.
CO-SPEVV-SB-C,
0.2 x 2P, 30 m max
(2 ports for MF/HF
DSC and VHF DSC)
NAV
NBDP Terminal
DP-5/6
MF/HF DSC
RECEIVER
AA-50
Option
Setting telecommand,
working freq., etc.
DSC distress
and safety
(continuous watch)
DSC signal,
telephony,
telex
DSC ship business and routine
(scanning watch)
DSC signal,
telephony,
telex
DSC distress
and safety
(continuous watch)
DSC ship business and routine
(scanning watch)
NAVTEX Receiver NX-500
2182 Watch receiver AA-45B
EGC Receiver EGC-5
DSC-6/6A
FS-1562
For DSC-6A
DPYC-1.25
(For PP-500)
(For PP-510)
FS-1562
NBDP Terminal
DP-5/6
MF/HF DSC
RECEIVER
AA-50
DSC-6/6A
For DSC-6A
299 11.8"
258 10.2"
143 5.6"
(95 3.7")
(95 3.7")
6 -˘7.5
254.1 10.0"
127 5.0"
89 3.5"
(89 3.5")
Weight: 3.5 kg
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300 Telefax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 1705-230303 Telefax: +44 1705-230101
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01
FURUNO ESPANA S.A.
Madrid, Spain
Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00 Telefax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950 Telefax: +47 70 127021
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-7098940 Telefax: +46 31-497093
FURUNO SUOMI OY
Helsinki, Finland
Phone: +358 9 3417570 Telefax: +358 9 3415716