1. INPUT JACK
Connect instrument cable here (
1
/4 inch jack).
2. MASTER VOLUME
Controls the total output level of amplifier.
3. GAIN
Controls the input level. Increasing gain
adds distortion, or an overdriven rock tone;
decreasing gain produces a cleaner sound.
Gain knob is functional when Overdrive
button is engaged.
4. OVERDRIVE ON/OFF SWITCH
ON selects the Overdrive (distortion) channel,
OFF selects the Clean channel. The GAIN
knob interacts with the overdrive button,
allowing the user to add the desired amount
of distortion.
5. LED
Indicates power on
/
off.
6. TREBLE
Adjusts high frequency output.
7. MIDDLE
Adjusts middle frequency output.
8. BASS
Adjusts low frequency output.
9. POWER
On/off switch.
10. PHONES
Connects to stereo headphones, which cancels
speaker output.
11. AUDIO IN
Input jack for external audio device such as
CD, MP3, or cassette player (device should
have its own volume control).
12. POWER INPUT / FUSE COMPARTMENT
Connection for power cable. Use only the
power cable supplied with this amplifier.
See instructions below for replacing the fuse.
1 5432 6 7 8
1211109
FACEPLATE
BACKPLATE
REPLACING THE FUSE
The fuse compartment contains an active fuse.
The fuse protects against power surges. If your
amplifier does not power up as usual, this fuse
may need to be replaced.
If the fuse fails:
1. Turn the amplifier power off.
2. Unplug the amplifier.
3. Detach the power cord and set aside.
4. Carefully insert a flathead screwdriver to
open the fuse compartment. Be careful not
to break the fuse inside.
5. Remove the blown fuse from the inner
(active) slot.
6. Replace with a 250V, 500mA fuse.
7. Close the fuse compartment.
8. Discard the blown fuse.
Note: If you replace the fuse and the amplifier
still does not power up, have the unit checked by
a qualified repairperson.
Open the fuse compartment.
Remove the blown fuse from the inner (active)
slot.
USING ANOTHER TYPE IS A POTENTIAL FIRE HAZARD.
CAUTION
REPLACE ONLY WITH SAME
TYPE 250V, 500mA FUSE.
ACTIVE FUSE
SPECIFICATIONS
Output Power:
10 watts RMS
Frequency Range:
40 Hz ~ 8 kHz
Speaker:
6.5" / 25W / 8 ohms
Input Sensitivity:
26 mV
Power Supply:
Detachable,
UL-approved
power cable
Dimensions: (LxWxH)
12" x 7.4" x 12"
Weight:
12 lbs.