18 AWG
(19/30)
0.048"
1.22 mm,
Bare Cu
6.2 ohms/
1k ft
20.3 ohms/
1 km
22 AWG
(7/30)
0.030"
0.76 mm,
Bare Cu
14.7 ohms/
1k ft
48.2 ohms/
1 km
18 AWG
(19/30)
0.048"
1.22 mm,
Bare Cu
6.2 ohms/
1k ft
20.3 ohms/
1 km
22 AWG
(7/30)
0.030"
0.76 mm,
Bare Cu
14.7 ohms/
1k ft
48.2 ohms/
1 km
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
Alum. Foil and
Tinned Cu
Braid (85%)
Alum./
Polyester Tape
with 24 AWG
Tinned Cu
Drain Wire
Under Tape
(100%)
26 ohms/
1k ft
85.3 ohms/
1 km
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
Alum./
Polyester Tape
with 24 AWG
Tinned Cu
Drain Wire
Under Tape
(100%)
26 ohms/
1k ft
85.3 ohms/
1 km
22-148-02 (500')
22-148-03 (1000')
CTL
2
insulated
conduct-
ors
2
insulated
conduct-
ors
2
insulated
conduct-
ors
2
insulated
conduct-
ors
0.065 1.65
0.068907817.3
90 7817.3
56.8
56.8
1.73
0.065 1.65
0.068 1.73
500
1000
152.4
304.8
Single:
red, black
500
152.4
1000 304.8
NEC CL2
CM
UL 1581
CSA FT-4
75 °C
Overall
cable
Overall
cable
21
44
9.5
20.0
22-119-02 (500')
22-119-03 (1000')
CTLP
22
9.9
46 20.7
Single:
white, violet
Shielded Pair:
0.140 3.56
Single:
white, violet
Shielded Pair:
0.140 3.56
Overall:
0.220 5.59
gray
Single:
red, black
Overall:
0.250 6.35
blue
NEC CL2P
CMP
UL 910
CSA FT-6
60 °C
Overall Cable:
Alum./
Polyester Foil
with 24 AWG
Tinned Cu
Drain Wire
(100%)
15 ohms/
1k ft,
49 ohms/
1 km
24 AWG
(7/32)
0.024"
0.61 mm,
Tinned Cu
24 ohms/
1k ft,
79 ohms
1 km
24
22-195-03 (1000')
CTL24LC-2P
2
shielded
twisted
pairs
251000 304.8 0.056 1.4211.3
Single:
red, black,
green, white
Overall:
0.215 5.46
blue
NEC CMP
UL 910
60 °C
conductor-
conductor
conductor-
conductor,
connected to
shield
16 52
30 98
68%
min. bend radius 2.5"
min. bend radius 5.0"
min. bend radius 4.0"
Part No.
(length)
Model
Description
dB/
100 m
MHz
Nominal
Capacitance
dB/
100 ft
Nominal
Attenuation
Nom.
Vel.
of
Prop.
Shipping
Weights
Standard
Lengths
Conductor
(stranding)
Diameter
Nom. DCR
Shielding
Materials
(% coverage)
Nom. DCR
Nom.
Imp.
(ohms)
No.
of
Cond.
Ft. m
Nominal
OD
Inch mm
Nominal
Core OD
Inch mm pF/ft pF/m
Lbs.kg
Composite Cable: (2) 18 AWG Insulated Conductors • (2) 22 AWG Insulated Conductors with Shield
Nonplenum Cable • Gas Injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
Plenum Cable • Gas-injected Foamed FEP Insulation • PVC and FEP Inner Jackets • Blue Flame-retardant PVC Outer Jacket
UL NEC/
C(UL) CEC
UL AWM
Temp.
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
USA West
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FAX
USA East
+1.919.863.1794 /+800.633.9876
+1.919.863.1797 FAX
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FAX
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Europe
+31.33.453.4040 /+800.3987.6673
+31.33.453.4050 FAX
Dubai
+971.4.2991800
+971.4.2991880 FAX
Asia
+65.6383.4400 /+800.7339.8766
+65.6383.4664 FAX
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
USA West
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FAX
USA East
+1.919.863.1794 /+800.633.9876
+1.919.863.1797 FAX
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FAX
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Europe
+31.33.453.4040 /+800.3987.6673
+31.33.453.4050 FAX
Dubai
+971.4.2991800
+971.4.2991880 FAX
Asia
+65.6383.4400 /+800.7339.8766
+65.6383.4664 FAX
CTL Series
utp & CoMMunICatIon CaBles
NOTE: Specifications are subject to change without notice.
All three CTL Series cables are suitable for interconnecting Extron MediaLink
™
Controllers to
MLS switchers, SCP Control Panels to System 5 IP and System 7SC switchers, as well as linking
other control system manufacturer's components to controllers and control panels. Depending
upon the model, the CTL Series cable is available in both NEC CMP plenum and NEC CM
non-plenum rated versions.
The CTL and CTLP cables feature two color-coded 18 AWG, double-shielded conductors, two
22 AWG low capacitance shielded twisted pair cables, and a drain wire providing excellent
performance and reduced interference. The CTLP cable features a plenum-rated jacket.
The CTL24LC-2P Low Capacitance Serial Control Dual Cable is a high performance solution
for transmission and distribution of serial control signals, such as RS-232 with handshake,
RS-422, and RS-485, in a variety of education, commercial, broadcast, and government serial
control A/V applications.
The CTL24LC-2P cable features four color-coded or two twisted pair 24 AWG tinned copper
insulated conductors within an overall outer aluminum polyester foil shield and a tinned
copper drain wire wrapped in a single jacket. The lead-free CTL24LC-2P cable is NEC CMP
plenum rated.
DesCRiPtion (continued)
729