Escort 3008B CD Player User Manual


 
10 Go/Nogomode
Page 2
Samplerate:samplingrateofthechannels
- internally ratedfrom 1 sto20min
- externally ratedthroughthe logicalchannel16
Blocks:divisionoftheinternalmemoryintoblocks
-1,2,4,8,16,32,64or128
- RazBlocks:deletingalltheblocks:thecurrentblockisthe#1block
Start:startconditionoftheacquisition
- Manual: withtheF2key Urgetriggering
- Trigger:withanassociationoftheanalogicalorlogicalchannels-seeChapter6
Trigger
- Waitingfor:afteradelayorataprecisedateandtime
- Automatic:immediate;automaticstopwhentheblockisfull
Pre-triggering:definitionofthepositionofthestarttriggerintheacquisition
-pre-triggerandpost-triggeroftheacquisition(beforeorafterStart);seechapter
MemoryMode
Real-timeSaving: simultaneousrecordingoftheacquisitionintoafile
-placeandnameofthesavingfile
-maximumlengthofthefile
Impossible isdisplayedwhenthesavingcapabilitiesareoverrun:reducethe
samplingrateorthenumberofchannels
Seechapter Filemode toknowthelimitationsofthefilerecording
Following:actionsaftertheendoftheacquisition
- Saveonfile:savingtheacquisitionintoafileifthereal-timesavingisnotvalidated
(orisimpossible)
- Plot:plottingtheacquisition
- Stop: noaction
- Rearm.:waitingforthestartcondition
- ChangeSetup:loadingaconfigurationandwaitingforthestarttrigger
10.2.Creationoftheframe
Makeanormalacquisitionordisplayapreviouslyrecordedfilewiththefunction Memory
output .
Inthepage Trigger ,selecttheparameter ChannelsforGo/Nogo then Visualizethe
frame then Modify .
Theappliancewillthendisplaythecurrentframe.Itappearsas2curves(aminandamaxcurve)
aroundthechannel selectedasareferencefortheframe.