PA2400T - 100V output U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
P
D
[W]
BTU/
hr
(3)
idle 230 0,3 44,3 0 44 151
Max. output power into 25ohms
(1)
230 8,9 1643 2x430 783 2672
1/3 max. output power into 25ohms
(1)
230 5,5 952 2x143 665 2270
1/8 max. output power into 25ohms
(1)
230 3,7 602 2x54 495 1687
1/8 max. output power into 25ohms
(2)
230 3,3 545 2x54 438 1493
1/8 max. output power into 25ohms
(2)
(4)
253 3,7 646 2x65 516 1760
Normal-Mode (-10dB) into 25ohms
(1)
230 3,3 540 2x43 454 1549
Rated output power (0dB, rated) into 25ohms
(1)
230 8,5 1550 2x400 750 2559
Alert-Mode (-3dB) into 25ohms
(1)
230 6,3 1119 2x200 719 2453
PA2250T - 100V output U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
P
D
[W]
BTU/
hr
(3)
idle 230 0,2 31,6 0 32 108
Max. output power into 40ohms
(1)
230 5,5 960 2x270 420 1433
1/3 max. output power into 40ohms
(1)
230 3,5 571 2x90 391 1334
1/8 max. output power into 40ohms
(1)
230 2,3 365 2x34 298 1015
1/8 max. output power into 40ohms
(2)
230 2,1 330 2x34 263 896
1/8 max. output power into 40ohms
(2)
(4)
253 2,3 385 2x41 303 1035
Normal-Mode (-10dB) into 40ohms
(1)
230 2,1 328 2x27 274 935
Rated output power (0dB, rated) into 40ohms
(1)
230 5,4 929 2x250 429 1464
Alert-Mode (-3dB) into 40ohms
(1)
230 4,0 668 2x125 418 1426
PA1250T - 100V output U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
P
D
[W]
BTU/
hr
(3)
idle 230 0,2 21,7 0 22 74
Max. output power into 40ohms
(1)
230 2,8 487 1x270 217 740
1/3 max. output power into 40ohms
(1)
230 1,8 289 1x90 199 679
1/8 max. output power into 40ohms
(1)
230 1,2 182 1x34 148 506
1/8 max. output power into 40ohms
(2)
230 1,1 170 1x34 136 465
1/8 max. output power into 40ohms
(2)
(4)
253 1,2 197 1x41 156 533
Normal-Mode (-10dB) into 40ohms
(1)
230 1,1 164 1x27 137 467
Rated output power (0dB, rated) into 40ohms
(1)
230 2,7 471 1x250 221 754
Alert-Mode (-3dB) into 40ohms
(1)
230 2,0 339 1x125 214 730
(1)
Onde sinus 1 kHz
(2)
Bruit rose selon norme EN60065
(3)
1BTU = 1055.06J = 1055.06Ws
(4)
10% au-dessus de la tension secteur
(5)
P
D
= Dissipation de la puissance
Les facteurs suivants permettent un calcul proportionnel direct du courant secteur (I
mains)
en fonction
des différentes tensions : 100V = 2,3; 120V = 1,9; 220V = 1,05; 240V = 0,96
Pour les modèles d’ampli de puissance équipés de transformateurs intégrés, les valeurs mentionnées
pour les sorties en 100V sont également applicables aux sorties en 70V, 50V et basse impédance, tant
que la charge connectée est aussi équivalente.