BRIDGED MODE Direct Output Isolated Outputs Direct Output Isolated Outputs
Output Definition 8Ω 200V 140V 50V 8Ω 200V 140V 50V
Load impedance or rated output voltage
Rated Load Impedance —— 57Ω 28Ω 3.6 Ω ——- 40Ω 19.6Ω 2.5 Ω
isolated outputs only
Rated Output Power 560 W 700 W 700 W 700W 600W 1000W 1000W 1000W
THD<0.2%, 45Hz ... 20kHz
Maximum Bridged Output Power 900W 820W 800W 780W 1200W 1180W 1160W 1140W
THD=1%, 1kHz
GENERELLPower Requirements 230V / 50Hz...60Hz
Power Consumption
at 1/8 maximum output voltage @ rated load impedance 690 W 870 W
Protections Audio limiters, High temperature, DC, HF, Back-EMF,
Peak current limiters, Inrush current limiters, Turn-on delay, Output Transformer Saturation Protection
Input Connectors Euro-style, 3pin, detachable or XLR
Output Connectors Euro-style, 12pin, detachable, covered
Cooling Front-to-Rear, 3-stage-fans
Regulations The appliances are in accordance with EN60065, EN50081-1, EN 50082-1
Safety Class I
Operating Temperature Range +5°C ... +40°C
Mounting Depht with Connectors 437 mm
Mounting Depht without Connectors 377 mm
Dimensions (W x H x D) 483mm x 132.5mm x 382mm
Weight (net) 20.5 kg 22.5kg
28