TION
Toll free: 1-877-536-3976
Local: 1-408-962-0515
atlona.com
5
RS-232
Connection
RS-232 is connected through a 9-pin female D connector. The pins will have functions associated
with them, some will be unassigned.
No. Pin Function
1 ---- Not used
2 Tx Transmit
3 Rx Receive
4 ---- Not used
5 Gnd Ground
6 ---- Not used
7 ---- Not used
8 ---- Not used
9 ---- Not used
Baud Rate: 9600bps Data Bit: 8bits Parity: None Stop Bit: 1bit
Command
The command codes are very sensitive, do not change capitalization, spacing, or lettering.
Command Feedback Description
PWON PWON Power on
PWOFF PWOFF Power off
All# All# Resets all inputs to corresponding outputs (in3 to out3)
x1$ x1$ Turns off output channel (to turn off output 3 = x3$)
x1AVx2 x1AVx2 Switch input to output (input 3 to output 5 = x3AVx5)
x1AVx2,x3,x4 x1AVx2,x3,x4 Switch input to multiple outputs (input 3 = x3AVx1,x2)
Statusx1 x7AVx1 Shows what input is connected to selected output
Status x1AVx1, x2AVx2,
x3AVx4, ....
Displays which inputs are currently connected to which outputs
Save[Y] Save2 Saves settings for future use, saves vary from 0 to 9
Recall[Y] Recall2 Pulls up saved settings for the number you selected
Clear[Y] C
lear2 Erases the save for the number you selected
Mreset Mreset Sets matrix back to the default settings
Each command or feedback is terminated with a carriage return.
Note: If the command fails or is incorrect the feedback should be “Command FAILED”
12345
9 8 7
6