MULTITASKER™
400-0209-002
12
12
Example:
Select the Output Volume command for the card
in slot #4. The current Output Volume level is
10, but it is not the optimal value. After sending
the following commands, an optimum volume
level of 15 is obtained:
1. [SELOC4]
The current volume level is 10.
2. [ – ] [ – ] [ – ]
The level is now 7 and is too low.
3. [+][+][+][+][+][+][+][+]
The level is now 15 and no further
adjustments are required.
10. [SELI]
This command sets the path to adjust the
INPUT volume level. The input volume range is
00 to 16 and is adjustable using the [+] and [-]
commands.
Command Format: [SELImCnUi]
m = Input (m = # from 1 to 3)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT113-100/101 is in slot #4. Adjust the
volume on Input 2 by sending the command
[SELI2C4] and then using the [+] and [-]
commands.
11. [SELO]
This command sets the path to adjust the
OUTPUT volume level. The output volume
range is 00 to 16 and is adjustable using the [+]
and [-] commands or the Volume Ramping
commands.
Command Format: [SELOCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example 1:
An MT113-100/101 is in slot #4. Adjust the
output volume by sending the command
[SELOC4] and then using the [+] and [-]
commands.
Example 2:
The output volume may also be adjusted using
key ramping commands. See the VOLUME
RAMPING FEATURE section of this manual for
details on using this feature.
12. [SELB]
This command sets the path to adjust the bass
level. The BASS level range is 00 to 16 and is
adjustable using the [+] and [-] commands.
Command Format: [SELBCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT113-100/101 is in slot #4. Adjust the
BASS on the output by sending the command
[SELBC4] and then using the [+] and [-]
commands.
13. [SELT]
This command sets the path to adjust the treble
level. The TREBLE level range is 00 to 16 and
is adjustable using the [+] and [-] commands.
Command Format: [SELTCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT113-100/101 is in slot #4. Adjust the
TREBLE on the output by sending the
command [SELTC4] and then using the [+] and
[-] commands.
14. [VLOA]
This command sets the OUTPUT volume to an
absolute value.