Agilent Technologies E8267D Stereo System User Manual


 
4
Step 8. Choose special options
Special options add unique capabilities to the signal generator for specific applications.
Ordering number Description Purpose Requires
E8267D-H18 Wideband modulation less than 3.2 GHz E8267D-016
E8267D-HBQ (China)
E8267D-HCC Add input and output of phase reference LO Provides multi-source phase coherency Z5623AKxx
Distribution Amplifier
(recommended)
E8267D-H1G Add 1 GHz external phase reference Provides multi-source phase coherency for
carrier frequencies 100 kHz to 250 MHz
E8267D-SP2 Dynamic sequencing Provides ability to change sequences on E8267D-602
command in the arbitary waveform generator
E8267D-HSQ
2
Add second set of IQ inputs Provides ability to switch between two E8267D-602
different external IQ inputs
E8267D-H1S Add 1 GHz external frequency reference input Enables use of an external frequency
reference to improve spectral purity
Step 9. Choose instrument connector configuration and accessories
Note: Standard 20 GHz models include a 3.5 mm (m) RF output connector on the front panel.
Standard 31.8 GHz and 44 GHz models include a 2.4 mm (m) RF output connector on the front panel.
Ordering number Description Purpose Requires
Standard with 3.5 mm (f) to 3.5 mm (f) Adapter set is included with the purchase of
E8267D-520 the 20 GHz models to connect to 3.5 mm (m).
Standard with 2.4 mm (f) to 2.4 mm (f) Adapter set is included with the purchase of
E8267D-532 and the 31.8 GHz and 44 GHz models to connect
E8267D-544 2.4 mm (f) to 2.9 mm (f) to 2.4 mm (m) and 2.9 mm (m).
E8267D-1ED
1
Type-N (f) RF output connector Type-N (m) to 3.5 mm (f) adapter set is E8267D-520
included with the purchase of the type-N (m)
connector.
E8267D-1EM Moves all front panel connectors to Simplifies cable management in rack mount
the rear panel environments.
E8267D-003 PSG digital output connectivity with N5102A E8267D-602, N5102A
E8267D-004 PSG digital input connectivity with N5102A E8267D-602, N5102A
E8267D-1CM Rackmount flange kit Provides a flange kit to mount the signal
5063-9215 generator into a standard EIA 19" rack.
E8267D-1CN Front handle kit Provides front handles for carrying the
5063-9228 instrument (not for rack mount).
E8267D-1CP Rack mount flange and front handle kit Provides front handles and a flange kit to
5063-9222 mount the signal generator into a standard
EIA 19” rack.
8120-8806 Master/slave interface cable Provides an interface cable to use two PSG's
in master/slave mode.
9211-2656 Transit case Provides a hard transit case to protect the
instrument during transit.
9211-7481 Transit case with wheels Provides a hard transit case with wheels to
protect the instrument during transit.
N5101A Baseband Studio PCI card Enables N5110B Baseband Studio E8267D-602, N5110B
N5101A-022 512 MSamples of waveform memory Waveform memory for the Baseband Studio N5101A
PCI card
N5102A Baseband Studio digital signal interface module Provides digital I/Q and digital IF E8267D-602,
inputs/outputs to/from the E4438C ESG E8267D-003,
and E8267D PSG vector signal generators. E8267D-004
N5110B Baseband Studio for waveform capture Allows playback of I/Q waveform data N5101A,
and playback directly from a PC hard drive or the optional E8267D-602
512 MSa waveform memory on the N5101A
to the E4438C ESG or the E8267D PSG vector
signal generator.
1. E8267D-1ED is not compatible with the 31.8 GHz or 44 GHz models.
2. E8267D-HSQ is not compatible with E8267D-1EH or E8267D-HCC.