Tascam CD-500/500B CD Player User Manual


 
TASCAM CD-500/500B 1
Updates
Always use the most recent rmware for this device.
Please visit the TASCAM web site at http://tascam.com/ to
check for the latest rmware.
Maintenance items
V1.11 fixes
When the fade out time was set, it did not function
properly when the π (pause) [JOG] button on the
unit or the π PAUSE button on the remote control was
pushed. This has been xed.
If the resume and power on play functions were ON,
the resume function did not work when the power was
turned ON. This has been xed.
When playing back tracks with the ash start function,
playback could become unstable depending on the
condition of the audio CD. This has been xed.
V1.10 fixes
The precision of playback time display has been
improved for MP3/WAV les (32/48 kHz).
If you pressed the
CALL button in program mode to
start playback from a paused state, playback started
from the rst track in the saved program. This has been
changed so that now playback starts from the pause
point.
Pressing the
SKIP Â button when stopped in
program mode started playback from the rst track
in the saved program. This has been changed so that
now playback starts from the nal track in the saved
program.
Confirmation of firmware version
Conrm the rmware version of your CD-500/500B before
conducting a rmware update.
1 Turn the unit’s power ON.
2 Enter menu mode, and select the
21 INFO
menu item. For details, see the “Menu operation
basics” section of the “4 – Menu” chapter in the CD-
500/500B Owner’s Manual.
3 Press the PITCH [MENU] knob on the main unit or
the ENTER button on the remote control to show
the system firmware version on the display.
Version Build number
If the rmware version shown here is the same or
newer than the rmware version that you planned to
update to, then there is no need to update it.
Firmware update procedures
Prepare a completely blank CD-R or CD-RW and a
computer that can create a data CD.
CAUTION
Be very careful not to cut the power to the unit during
rmware updating. If the power should be interrupted
during rmware updating, the unit could become
unstartable or otherwise damaged.
1 Download the file
Download the latest rmware from the TASCAM
website (http://tascam.com/). Uncompress the
downloaded le if it is in a ZIP format or otherwise
compressed.
2 Create a data CD for updating the unit
Write the downloaded rmware les to the disc.
(V1.11, for example, uses 8 rmware les: C5B00111.
upd, C5C00111.upd, C5D00111.upd, C5M00111.
upd, C5R00111.upd, C5R10111.upd, C5S00111.upd
and C5S10111.upd.) Use ISO 9660 Level 1 (MS-DOS-
compatible) Disc At Once format to write the CD-R or
CD-RW.
3 Update the firmware
1) Turn the unit’s power on.
2) Conrm that
no disc
appears on the display.
While pressing and holding both the SEARCH Ô
[A.CUE] and SEARCH [A.READY] buttons on
the unit, press the EJECT button.
3) Conrm that
UPDATE IN
appears on the
display, and insert the update data CD.
CD-500/500B
Release Notes
D01153220B