If you are using terminal lugs, connect them to the wires. If you are
attaching bare wires directly to the speaker connectors, separate the
wire conductors and strip back the insulation from the end of each
conductor. Be careful not to cut into the wire strands. Unscrew (turn
counterclockwise) the speaker connector collar. Place the connector lug
around the shaft, or insert the bundled wire into the hole in the shaft.
Turn the collars clockwise to clamp the connector lug or wire fi rmly in
place.
NOTE: Be sure there are no loose wire strands that could touch
adjacent wires or connectors.
Troubleshooting
Most diffi culties in audio systems are the result of poor or wrong
connections, or improper control settings. If you encounter problems,
isolate the area of the diffi culty, check the control settings, determine
the cause of the fault and make the necessary changes. If you are
unable to get sound from the amplifi er, refer to the suggestions for the
following conditions:
Front Panel Power Indicator Is Not Lit
No mains power to the amplifi er. Check AC power connections at
the amplifi er and the AC outlet. Check the front panel power switch.
Make sure that it is set to the ON position. If using 12V trigger power-
on, make sure that a trigger signal is present at rear panel screw
terminals.
No Sound
If the amp is getting AC power, but is producing no sound, check
the PROTECTION INDICATOR on the front panel. If lit, see below. If
not, check all of your connections and control settings on associated
components. Make sure that your input connections and speaker
connections match your selected confi guration.
Protection Indicator Is Lit
The front panel PROTECTION INDICATOR is lit when the amplifi er
protection circuits have shut off the amplifi er. Typically, this occurs
only when the amplifi er has overheated, when there is faulty speaker
wiring, or after a period of extreme use. Turn off the system and wait
for the amp to cool. Then push the front panel power switch in and
out to reset the protection devices. If the problem is not corrected or
reoccurs, there is a problem with the system or the amplifi er itself.
Specifi cations
RMB-1565
Continuous Power Output
Continuous Power Output 100 watts/channel
(20-20 kHz, < 0.03%, 8 ohms)
Total Harmonic Distortion
Total Harmonic Distortion (20Hz-20kHz, 8 ohms) < 0.03%
Intermodulation Distortion
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03%
Frequency Response
Frequency Response ( ±1dB) 10Hz - 40kHz
Damping Factor
Damping Factor (20-20,000 Hz, 8 ohms) 200
Speaker Impedance
Speaker Impedance (Normal mode) 4 ohms minimum
Signal to Noise Ratio
Signal to Noise Ratio (IHF A network) 105 dB
Input Impedance/Sensitivity
Input Impedance/Sensitivity 8.2 k Ohms/1.25 volt
Power Requirements
Power Requirements 110 -240 Volts, 50-60 Hz
Power Consumption
Power Consumption 250 Watts
Dimensions
Dimensions
Width x Height x Depth 431 x 99 x 339 mm
17 x 3
7
/8 x 13
3
/8 ins.
Front Panel Height 2U
Weight
Weight (net) 6 kg, 13.23 lb.
RMB-1575
Continuous Power Output
Continuous Power Output 250 watts/channel
(20-20 kHz, < 0.03%, 8 ohms)
Total Harmonic Distortion
Total Harmonic Distortion (20Hz-20kHz, 8 ohms) < 0.03%
Intermodulation Distortion
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03%
Frequency Response
Frequency Response ( ±1dB) 10Hz - 80kHz
Damping Factor
Damping Factor (20-20,000 Hz, 8 ohms) 400
Speaker Impedance
Speaker Impedance (Normal mode) 4 ohms minimum
Signal to Noise Ratio
Signal to Noise Ratio (IHF A network) 109 dB
Input Impedance/Sensitivity
Input Impedance/Sensitivity 8.3 k Ohms/1.5 volt
Power Requirements
Power Requirements
U.S. version 120 Volts, 60 Hz
European version 230 Volts, 50 Hz
Power Consumption
Power Consumption 600 Watts
Dimensions
Dimensions
Width x Height x Depth 431 x 144 x 406 mm
17 x 5
11
/16 x 16 ins.
Front Panel Height 3U
Weight
Weight (net) 11 kg, 24.25 lb.