Pioneer V2550BU Home Theater System User Manual


 
INSTALLATION AND ASSEMBLY
24
(1) Weight-tolerant
The ground must be flat and horizontal. It should be able to bear the weight of the system.
For wooden floors, if the part receiving the weight of the system lies at the center between the reinforcement
beams below the floor, the floor may become deformed or may curve inwards. Moreover, in the case of a carpet
etc., the part bearing the load may sink with time, meaning that the horizontal balance of the system may shift
out of place after installation. In such cases, lay a more than 12 mm thick board below the system to distribute
the weight of the system on the floor.
For concrete floors, it may not be possible to install the system horizontally due to the roughness of the floor. In
such cases, do the same as above.
(2) Ceiling height
Reserve a headroom of at least about 10 cm (4 inches) between the top of the system and the ceiling. If an air
conditioner outlet or illumination lamp is located above the system, use special care to prevent troubles due
to dust, temperature, humidity and dew condensation. In case the system is covered by interior furnishings,
be sure to take measures to ventilate Floor leveler tends to pool above the top of the system. Otherwise
troubles may result.
(3) Front space
Finger and hand prints form easily on the face of the screen. Therefore make sure viewers cannot touch it
directly.
Leave workspace in front for replacing the screen.
(4) Rear space
The system can be installed up against the wall when the projection units are stacked in two stages. When
they are stacked in three stages, reserve a rear clearance of at least 5 cm (2 inches). However, remember that
a space of at least 50 cm (20 inches) is required in the maintenance operation and install the system by taking
later maintenance in consideration.
(5) Stacking stages
The projection units can be stacked in up to three stages.
They cannot be stacked in four stages or more.
Otherwise troubles may result in relation with the cabinet strength or stagnation of heat.
Up to 4 columns of RM-V2550S2 screens can be placed in a row.
(Maximum number of screens is thus 12 [3 x 4])
1. INSTALLATION CONDITIONS
CHAPTER 3. INSTALLATION AND ASSEMBLY