For Concrete Ceilings use ceiling plate (A) as a
template, drill four 5/16" (8 mm) dia. holes to a
minimum depth of 1-3/4" (45 mm).
Attach using concrete expansion anchors as shown.
Tighten to 80 in. • lb (9 N.M.) maximum torque.
Note: Fasteners for concrete ceilings are not included,
order ACC 210 accessory kit.
© 2006 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark of Peerless Industries, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Align hole in ceiling plate (A) with hole in ceiling.
Gently hammer in concrete anchor as shown.
Use a 10 mm wrench (not provided) to tighten concrete
anchor to 80 in. • lb (9 N.M.) maximum torque as
shown.
Make sure that the supporting surface will safely
support the combined load of the equipment and all
attached hardware and components.
Never exceed the Maximum Load Capacity of 250 lb
(113.4 kg).
WARNING
Tighten concrete anchor bolt firmly, but do not over-
tighten. Overtightening can damage the bolt, greatly
reducing its holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
FOR PRODUCT SAFETY USE ONLY RAWL
#5005
OR HILTI
HL814 CONCRETE ANCHORS. Order
ACC 210 accessory kits, each contains four .312" x
1.625" (8 mm x 41 mm) concrete expansion anchors.
Concrete expansion anchors are not intended for
attachment to concrete covered with a layer of
plaster, drywall, or other finishing material.
Always attach concrete expansion anchors directly to
load-bearing concrete.
Never attach concrete expansion anchors to concrete
covered with plaster, drywall or other finishing material.
If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown in Figure 1.
WARNING
Figure 1
A
A
ACC 210