8.3 Wiring Precautions the Part which Matches the EMC Directives
8.3.1 Method to connect the power wire and ground wire
8.3 Wiring Precautions the Part which Matches the
EMC Directives
Connect and wire GOT equipment as instructed below.
If the GOT equipment is configured in a way that differs from the following instructions
then the system will not comply with EMC directives.
8.3.1 Method to connect the power wire and ground wire
(1) With the power wire, be sure to attach the ferrite core (TDK type ZCAT3035-1330) within 90 mm of
the GOT terminal module.
Lead the power wire and ground wire as shown in Section 8.1.2 (2).
Always ground the FG wires.
*1 Wrap the power wire around the ferrite core.
<For A95*GOT>
0V 24V
INPUT
<For A956WGOT>
Within 90mm (3.54 inch)
Ferrite core
GOT terminal block
*1
GOT terminal block
Within 90mm (3.54 inch)
Ferrite core
*1