Listen Technologies LA-350 Stereo Receiver User Manual


 
56
LA-140
LT-82
Design Guide
Design Guide
LA-140
6
Set Termination Switch
6A
Always set the termination switch to the “ON” position in single radiator systems.
Single Radiator Systems
7
If desired, the three LED indicators on the front of the radiator can be disabled using this switch. Set this
switch to the position towards the left side of the rear of the radiator to disable the LED indicators.
To enable the LED indicators set this switch to the position towards the right side of the rear of the radiator.
Set LED Indicator Shuto Switch (SW1)
6B
Set the termination switch to the “OFF” position on all radiators
that are outputting an RF signal to another radiator.
Set the termination switch to the “ON” position on the radiators
that are not outputting an RF signal to another radiator.
Multiple Radiator Systems
5
Set Delay Compensation Switch
5A
The position of the delay compensation switch does not matter in single radiator systems.
Single Radiator Systems
5B
It is necessary to select the correct delay compensation switch
setting for each radiator to ensure that each radiator transmits
the same signal at exactly the same time in an overlapping
,multiple radiator system. Not setting the delay compensation
switch correctly will result in reduced coverage area for the
system. See design guide page 16 for determining the correct
delay compensation switch setting for each radiator in a multiple
radiator system.
Multiple Radiator Systems
LED Indicator Shutoff Switch (SW1)
Delay Compensation Switch
Termination Switch
LA-140 Setup and Operating Instructions