Listen Technologies CU 6010 Stereo Receiver User Manual


 
Danish Interpretation Systems User Manual
Manual 01 18 04438
28
MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011
This table shows the maximum number of MU
6040 Microphone Units, which can be connected to
each of the four outputs
(A1, A2, B1 or B2)
on a CU
6010/6011 Central Unit or on each output on an EX
6010 Extension Unit or on the output of a PS 6000.
The numbers are valid with no audio in loudspeaker
(no loudspeaker connected to each unit). If
loudspeakers are used, then use the figures for
CM/DM 60x0P above.
Length of Feeding Cable,
Type CAT5 AWG24
Cable length between
each MU 6040
Total cable length Max. number of
MU 6040
10 m 2 m 168 m 80
30 m 2 m 178 m 75
50 m 2 m 188 m 70
100 m 2 m 200 m 51
150 m 2 m 200 m 26
100 m 1 m 151 m 52
150 m 1 m 191 m 42
IS 6132P Interpreter Units – CU 6010/6011
The tables below shows the maximum number of IS
6132P Interpreter Sets, which can be connected to
each of the four outputs
(A1, A2, B1 or B2)
on a CU
6010/6011 Central Unit or on each output on an EX
6010 Extension Unit or on the output of a PS 6000.
The numbers are with no audio in loudspeaker (no
loudspeaker connected to each unit).
If loudspeakers are used, then use the figures for
CM/DM 60x0P above.
Note: The number of units is dependant of how
many interpreter sets there are per booth (or
language), as there only can be one set switched ON
per language (channel).
Length of Feeding Cable,
Type CAT5 AWG24
Length of inter-connecting Cables,
Type CAT5 AWG24
Max. number of units pr output
All ON ½ ON 1/3 ON
10m 2 m 54 x x
30m 2 m 49 57 60
50m 2 m 44 51 x
100m 2 m 35 40 x
150m 2 m 25 30 x