Listen Technologies CU 6010 Stereo Receiver User Manual


 
Danish Interpretation Systems User Manual
Manual 01 18 04438
26
Length of Feeding Cable,
Type CAT5 AWG24
Length of Ca
ble between each
JB 6002, Type CAT5 AWG24
Total cable
length
Number of
JB 6002
Max. number of
DM 60x0
10 m 3 m 61 m 18 36
30 m 3 m 75 m 16 32
50 m 3 m 89 m 14 28
100 m 3 m 127 m 10 20
150 m 3 m 168 m 7 14
CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011
The following table shows the maximum number of
units, which can be connected to each of the four
outputs
(A1, A2, B1 or B2)
on a CU 6010/6011
Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of
CM/DM 60x0 pr output
10 m 1 m 39 m 30
30 m 1 m 56 m 27
50 m 1 m 73 m 24
100 m 1 m 115 m 16
150 m 1 m 160 m 11
10 m 2 m 64 m 28
30 m 2 m 78 m 25
50 m 2 m 94 m 23
100 m 2 m 130 m 16
150 m 2 m 170 m 11
CM/DM 6560F Chairman/Delegate Units – CU 6010/6011
The following table shows the maximum number of
units, which can be connected to each of the four
outputs
(A1, A2, B1 or B2)
on a CU 6010/6011
Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter-connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of CM/DM
60x0 pr output
10 m 1 m 35 m 27
30 m 1 m 53 m 24
50 m 1 m 70 m 21
100 m 1 m 113 m 14
150 m 1 m 159 m 10
10 m 2 m 58 m 25
30 m 2 m 72 m 22
50 m 2 m 88 m 20
100 m 2 m 126 m 14
150 m 2 m 166 m 9