Listen Technologies CU 6005 Stereo Receiver User Manual


 
Danish Interpretation Systems User Manual
Manual 01 18 04438
27
DC 6990P Conference Units – CU 6010/6011
The following table shows the maximum number of
units, which can be connected to each of the four
outputs
(A1, A2, B1 or B2)
on a CU 6010/6011
Central Unit or on each output on an EX 6010
Extension Unit or on the output of a PS 6000.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of
DC 6990P pr output
10 m 1 m 35 m 26
30 m 1 m 53 m 24
50 m 1 m 70 m 21
100 m 1 m 112 m 13
150 m 1 m 158 m 9
10 m 2 m 56 m 25
30 m 2 m 72 m 22
50 m 2 m 90 m 19
100 m 2 m 124 m 13
150 m 2 m 166 m 9
DC 6990P Conference Units – CU 6005
The following table shows the maximum number of
units, which can be connected to the two outputs
(A1 and A2) simultaneously on a CU 6005 in total
If only one chain is used the information in the
above table must be used.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length Max. number of
DC 6990 for both outputs
10 m 1 m 2x34 m 2x15
30 m 1 m 2x43 m 2x14
50 m 1 m 2x62 m 2x13
100 m 1 m 2x110 m 2x11
150 m 1 m 2x158 m 2x9
10 m 2 m 2x36 m 2x14
30 m 2 m 2x54 m 2x13
50 m 2 m 2x90 m 2x12
100 m 2 m 2x118 m 2x10
150 m 2 m 2x164 m 2x8