Beyerdynamic MCS-D 200 Speaker System User Manual


 
MCS-D 200 Control Unit
E
11
3.2.5 Rack mounting
When mounting the MCS-D 200 control unit into a 19"-rack housing leave 1 U for a ventilation panel above and
under the control unit.
Make sure that the mains switch, mains plug and all connection on the rear of the device are easily accessible.
3.2.6 How to supply the system
All microphone stations, D/A interfaces and adapters are powered via the system. They do not have their own power supply.
The number of the required power supply units depends on the number of microphone stations and the system set-up
including different cable lengths and operating mode.
The following list shows how many devices such as microphone stations, interfaces and adapters can be powered by the
system.
MCS-D 200 control unit with 1 power pack (= 2 A) for approx. 15 microphone stations
MCS-D 200 control unit with 2 power packs (= 4 A) for approx. 30 microphone stations
When the system is extended with additional power supply units:
Power supply unit with 1 power pack (= 2 A) for approx. 15 microphone stations
Power supply unit with 2 power packs (= 4 A) for approx. 30 microphone stations
Power supply unit with 3 power packs (= 6 A) for approx. 45 microphone stations
Note:
In this rule of thumb, an adapter (CA 4212/13/14 or CA 4222/23/24) approximately counts as half a microphone station.
Example of a system set-up:
1 MCS-D 200 control unit with 2 power packs . . . . . . . . . . . . 10 MCS-D 202 interpreter stations
+ 1 D/A interface
+ 2 adapters
+
1 Power supply unit with 2 power packs. . . . . . . . . . . . . . . . . for 30 microphone stations
+
1 Power supply unit with 3 power packs. . . . . . . . . . . . . . . . . for 45 microphone stations
3.2.4 How to connect a PC or media control system
If you would like to connect a PC or media control system to the MCS-D 200 control unit, use the RS 232 connection or .
In order to connect a PC use a standard RS 232 cable, straight - no null modem cable. If you connect other devices, please
observe the pin assignment.
The system is configured via the MCS-D 200 control unit, please refer also to chapter 3.3 “How to operate the menu of the
MCS-D 200 control unit”.
14 15
14 15