Andrew 9.3-Meter ESA Stereo System User Manual


 
Grounding Cable
Attachment
Step 1
27
Installation Procedures
Figure 22
Note: Thoroughly clean exposed portions of grounding cables, unplated portion of uni-
versal terminals and corresponding mounting surfaces using a wire brush. Liberally apply
supplied 203233-2 conductive grease to all connection surfaces prior to and after instal-
lation. Thoroughly remove conductive grease from hands and tools using soap and water.
Refer to Figure 22. Remove existing 7/8 by 2-1/4 in (57 mm) hardware at indicated posi-
tions and install grounding cables as shown.
Use supplied 7/8 by 2-3/4 in (70 mm) hardware