AMX DAS-T0808-SIG Stereo System User Manual


 
Serial Control Strings
77
Mi Series and Tango Audio Controllers
Command Messages (Cont.)
MGSSs Get Source Status, where:
‘s’ is the desired source, (1-8)
Source Status:
"MSSTs,p[variable]"
where:
1) 's' is the source, valid values are 1-8
2) 'p' is the source state, valid values are:
0: Off
1: On
2: Paused
3) [variable] is a data string which varies
with the type of source:
0: undefined - p where:
1: AM/FM Tuner - b,m,fffff where:
'b' is the band: 1 = AM, 2 = FM
'm' is the mono/stereo status:
1 = mono, 0 = stereo
'f' is the currently tuned frequency
(if it is known)
2: CD Changer
3: DVD Player
4: Satellite Receiver
5: Audio Server
6: Other
20: Internal AM/FM Tuner - b,m,s,fffff
where:
'b' is the band: 1 = AM, 2 = FM
'm' is the mono/stereo status:
1 = mono, 0 = stereo
's' is the seek/tune status:
'1' = seek, '0' = tune
'f' is the currently tuned
frequency
- or -
ERR
CSSTh,m,s Set the Clock Time, where:
1) ‘h’ is the desired hour, (0-23)
2) ‘m’ is the desired minute, (0-59)
3) ‘s’ is the desired second, (0-59)
Clock Status:
"RCSTh,m,s"
- or -
ERR
CGST Get the Clock Time. Clock Status:
"RCSTh,m,s"
- or -
ERR
CSALr,s,v,h,m Set the Clock Alarm, where:
1) 'r' is the desired room, (1-64)
2) 's' is the desired source, (1-8)
3) 'v' is the desired volume, (0-70, 101)
"101: Mute
"0..70: 0..-70 dB
4) 'h' is the desired hour, (0-23)
5) 'm' is the desired minute, (0-59)
Alarm Status:
"CALMr,s,v,h,m"
- or -
ERR
CCALr Clear the Clock Alarm, where 'r' is the
desired room. (0-64).
0: clear the alarm for all rooms
1-64: clear the alarm for the specified room
Alarm Status:
"CALMr,0,0,0,0"
See "CSALr,s,v,h,m" (above)
- or -
ERR