AMX DAS-T0808-SIG Stereo System User Manual


 
Serial Control Strings
72
Mi Series and Tango Audio Controllers
Command Messages (Cont.)
MRRGr Remove Room from Group, where:
‘r’ is the room to remove, (1-64)
Note: The Room Grouping will be removed if
less than 2 rooms are associated with the
given source.
Room Grouping Status:
"MRGSz,s,b8,b7,b6,b5,b4,b3,b2,b1"
where:
1) 'z' is the zone ID, valid values are:
0: no zone ID - all rooms in selection
are not in a grouping
1..32: zone ID
2) 's' is the source the rooms are
currently associated with
3) 'b8'…'b1' is a binary room selection
bitmap where all rooms to be grouped
have a binary 1 in the room position.
The most significant bit in 'b8' is for
room 64 and the least significant bit in
'b1' is for room 1.
Note: If none of the bits are set in the room
selection bitmap, then the room grouping has
been removed.
- or -
ERR
MDRG
MDRGz
Dissolve all Room Groupings
Dissolve room groupings and turn all zones
off.
1) if 'z' is used, the zone 'z' will remain on
ACK
- or -
ERR
MGRGr Get Room Grouping, where:
‘r’ is any room in the grouping, (1-64)
Room Grouping Status:
"MRGSz,s,b8,b7,b6,b5,b4,b3,b2,b1"
where:
1) 'z' is the zone ID, valid values are:
0 : no zone ID - all rooms in selection
are not in a grouping
1..32 : zone ID
2) 's' is the source the rooms are currently
associated with
3) 'b8'…'b1' is a binary room selection
bitmap where all rooms to be grouped
have a binary 1 in the room position.
The most significant bit in 'b8' is for
room 64 and the least significant bit in
'b1' is for room 1.
Note: If none of the bits are set in the room
selection bitmap, then the room grouping has
been removed.
- or -
ERR
MIGVr,i Increment the Volume for a Room Grouping,
where:
1) ‘r’ is any room in the grouping, (1-64)
2) ‘i’ is the increment value or 0 for system
default
Volume Status:
"MVLr,v"
where:
1) 'r' denotes the room in the group,
values are 1-64
2) 'v' denotes the volume setting, values
are:
101: Mute
0..100: 0..-100 dB
- or -
ERR