AMX DAS-T0808-SIG Stereo System User Manual


 
Serial Control Strings
70
Mi Series and Tango Audio Controllers
Command Messages (Cont.)
MSBLr,x Set Room Balance, where:
1) 'r' is the desired room, (1-64)
2) 'x' is the balance value, (0-20):
0: balanced evenly
1..10: Full Left..10% Left
11..20: 10% Right .. Full Right
Room Balance Status:
"MBALr,x"
where:
1) 'rr' denotes the room 1-64
2) 'x' denotes the balance, values are:
0: balanced evenly
1..10: 100% ... 10% Left
11..20: 10% .. 100% Right
- or -
ERR
MGBLr Get Room Balance, where:
‘r’ is the desired room, (1-64)
Room Balance Status:
"MBALr,x"
where:
1) 'rr' denotes the room 1-64
2) 'x' denotes the balance, values are:
0: balanced evenly
1..10: 100% ... 10% Left
11..20: 10% .. 100% Right
- or -
ERR
MSPRr,x Set Room Privacy, where:
1) 'r' is the desired room, (1-64)
2) 'x' is the desired privacy state, (0-1)
0: Off
1: On
Privacy Status:
"MPRVr,x"
where:
1) 'r' denotes the room 1-64
2) 'x' denotes the privacy status, values are:
0: Off
1: On
- or -
ERR
MGPRr Get Room Privacy, where:
‘r’ is the desired room, (1-64)
Privacy Status:
"MPRVr,x"
where:
1) 'r' denotes the room 1-64
2) 'x' denotes the privacy status, values are:
0: Off
1: On
- or -
ERR