AMX Duet Module Interface Specifications
51
Mi-Series & Tango Audio Controllers
Levels
The UI module controls the Tango Controllers via level events (NetLinx command SEND_LEVEL) sent to the
COMM module.
The levels supported by the COMM module are listed below.
These levels are associated with the virtual device(s) and are independent of the levels associated
with the touch panel device.
An '*' indicates an extension to the standard API.
Command Control
The UI module controls the Tango Controllers via command events (NetLinx command SEND_COMMAND)
sent to the COMM module.
The commands supported by the COMM module are listed below.
Not all sources will work with all the commands listed below. Depending on how the device is
programmed each source has it's own set of applicable commands/channels (see the Input Source
Types section on page 56).
Mi-Series & Tango Controllers - Levels
Level Description
1 Volume Level (range 0…255)
2 Balance Level (range 0…255)
3 Bass Level (range 0…255)
4 Treble Level (range 0…255)
*8 Page Volume Level (range 0…255)
Mi-Series & Tango Controllers - Command Control
Command Description
?BAND Get the currently selected tuner band.
This query should be issued on the port matching the source number you want to
query.
Syntax:
?BAND
Replies with BAND-<band>
Example:
?BAND
?DEBUG Request the state of the module debug feature.
Syntax:
?DEBUG
This query should be issued on port 1.
Replies with DEBUG-<value>
Example:
?DEBUG
DEBUG Set the state of debugging messages in the module.
Syntax:
DEBUG-<value>
This command should be issued on port 1.
<value>:
• 1 = set only error messages on
• 2 = set error and warning messages on
• 3 = set error, warning & info messages on
• 4 = set all messages on
Example:
DEBUG-1